STATUS CODE IMS
AA - EXPLANACAO:
CALL GHNG OU ISRT IGNORADO PORQUE AO INVES DE
ESPECIFICAR UM TERMINAL LOGICO, A
PCB ALTERNADA ESPECIFICOU
UM
NOME DE TRANSACAO COMO DESTINO. UMA PCB DE RESPOSTA ALTER-
NADA
DEVE ESPECIFICAR UM TERMINAL LOGICO COMO DESTINO
-
ATITUDE: CORRIJA O CALL EMITIDO.
AB - EXPLANACAO: UMA I/O AREA E REQUERIDA
COMO UM DOS PARAMETROS
DESTE CALL E NAO FOI ESPECIFICADA
-
ATITUDE: CORRIJA O CALL INCLUINDO O ENDERECO DE UMA I/O
AREA
COMO PEDIDO.
AC - EXPLANACAO: HA UM ERRO EM UMA DAS SSAS
NUM CALL GET OU ISRT
DEVIDO A UMA DAS SEGUINTES RAZOES
.O
DL/I NAO PODE ENCONTRAR UM SEGMENTO NA DB PCB ESPECIFICA-
DA
QUE TENHA O NOME DE SEGMENTO DADO NA SSA
.O
NOME DO SEGMENTO ESTA NA DB PCB MAS A SSA SSA QUE ESPECI-
FICOU NAO O FEZ NA SEGUENCIA HIERARQUICA
.O
CALL ESPECIFICA DUAS SSAS PARA O MESMO NIVEL HIERARQUICO
- ATITUDE:
CORRIJA O NOME DO SEGMENTO NA SSA
AD - EXPLANACAO: PARAMETRO FUNCAO DO CALL
INVALIDO. O IMS RETORNA
UM
STATUS AD SE NAO RECONHECE A FUNCAO FORNECIDA. SE A FUNCAO
ESTA
CORRETA, ALGUMAS OUTRAS CAUSAS POSSIVEIS SAO.
.REFERENCIAR UMA PCB DB OU ALTERNADA NUM CALL GHKP UM CALL
GHKP DEVE REFERENCIAR UMA I/O PCB
.EMITIR UM GU OU GN PARA UMA MENSAGEM REFERENCIANDO UMA PCB
ALTERNADA AO INVES DE UMA I/O PCB
.REFERENCIAR UMA PCB ALTERNADA OU DE I/O PARA UM CALL DB
.REFERENCIAR UMA DB PCB NUM CALL DE MENSAGEM
.EMITIR UM ROLB QUE INCLUA O ENDERECO DE UMA I/O AREA COMO UM
DOS PARAMETROS NUMA BMP ORIENTADA PARA BATCH
-
ATITUDE: SE VOCE RECEBEU ESTE STATUS NUM CALL DE MENSAGEM DB
OU
CHKP CORRIJA O CALL PARA REFERENCIAR A PCB CORRETA SE FOI
NUM
CALL ROLB OU NUMA BMP REMOVA A I/O AREA DO CALL
AH - EXPLANACAO: O PROGRAMA EMITIU UM CALL
ISRT SEM INCLUIR QUAIS
QUER
SSAS. CALLS ISRT REQUEREM UMA SSA. SE O CALL FOI UM GU
PARA
UM BANCO DE DADOS GSAM FALTOU ESPECIFICAR UMA RSA
- ATITUDE: CORRIJA O CALL ISRT
INCLUINDO UMA SSA OU O CALL GU
INCLUINDO UMA RSA.
AI - EXPLANACAO: UM ERRO DE OPEN OCORREU,
ALGUMAS CAUSAS POSSIVEIS
SAO.
.HA
UM ERRO NOS CARTOES DD
.O
OPEN NAO ESPECIFICOU MODO DE CARGA E O ARQUIVO ESTAVA VA-
ZIO. UM ARQUIVO VAZIO REQUER UMA PCB COM OPCAO DE CARGA
.O
BUFFER E PEQUENO DEMAIS PARA MANTER UM REGISTRO EM TEMPO
DE OPEN.
CONTATE O DBA
.FALTOU FORNECER CARTOES DD PARA O BANCO DE DADOS LOGICAMENTE
MENTE RELACIONADOS
.PARA UM ARQUIVO OSAM, O CAMPO DSORG NA DCB, DSCB OU JFCB NAO
NAO
ESPECIFICA PS OU DA
.PARA UM ARQUIVO OSAM ANTIGO O CAMPO BUFL OU BLKSIZE NA DSCB
E
ZERO
.O
ARQUIVO ESTA SENDO ABERTO PARA CARGA MAS A OPCAO PARA UM
GU
OU MAIS SEGMENTOS E DIFERENTE DEL L OU LS
.ALOCACAO DE ARQ. OSAM INVALIDA.
PROVAVELMENTE ESTA (1..1)
AO
INVES DE (1,1) E ISTO FAZ COM QUE O DSORG SEJA PC.
.A
OPCAO DE PROCESSAMENTO E L.O ARQUIVO OSAM E ANTIGO. E A
DSCB LRECL E/OU BLKSIZE NAO BATEM COM O LRECL E/OU BLKSIZE
DA
DBD.
.INFORMACAO INCORRETA OU EM FALTA NAO PERMITIU AO IMS DETER-
MINAR O BLKSIZE OU O TAMADO DO REGISTRO LOGICO
.UM
CATALOGO NAO ESTAVA DISPONIVEL PARA PERMITIR O ACESSO A
UM
BANCO DE DADOS VSAM
.O
SISTEMA OPERACIONAL NAO FEZ O OPEN
SE O
IMS ENVIA A MENSAGEM DFS0730I VOCE PODE DETERMINAR A CAU
SA
DA FALHA DO OPEN.
-
ATITUDE: ESTES PROBLEMAS FREQUENTEMENTE REQUEREM A ASSISTEN-
CIA
DE UMA PESSAO DA AREA DE SUPORTE MAS ANTES HA ALGUMAS
COISAS QUE VODE DEVE FAZER:
.VERIFIQUE OS CARTOES DD. CERTIFIQUE-SE QUE O NOME DO CARTAO
DD
EO MESMO ESPECIFICADO NO PARAMETRO DATASET NA DBD. NA DB
PCB
NA AREA DE NOME DO SEGMENTO APARECE O NOME DO CARTAO DD
QUE
NAO PODE SER ABERTO.
.VERIFIQUE A PSB E CERTIFIQUE-SE QUE AS OPCOES APROPRIADAS DE
PROCESSAMENTO FORAM ESPECIFICADAS PARA CADA UMA DAS DB PCB'S
QUE
SEU PROGRAMA FAZ USO.
AJ - EXPLANACAO: O FORMATO DE UMA DE SUAS
SSAS ESTA INVALIDO
ALGUMAS DAS POSSIVEIS RAZOES PARA
ISTO SAO:
.A
SSA CONTEM UM COMMAND CODE INVALIDO PARA O CALL
.O
OPERADOR RELACIONAL NA QUALIFICACAO INVALIDO
.FALTA UM PARENTESES A DIREITA OU UM CONECTOR BOOLEANG NA
QUALIFICACAO
.CALL DLET COM SSAS MULTIPLAS OU QUALIFICADAS
.CALL REPL COM SSA QUALIFICADA
.CALL ISRT COM A ULTIMA SSA QUALIFICADA
.CALL ISRT PARA LOGICAL CHILD COM COMMAND CODE D.
CALL ISRT PARA LOGICAL CHILD NAO PODEM USAR PATH CALLS.
.PARAMETRO RSA NUM CALL GSAM INVALIDO
-
ATITUDE: CORRIJA A PORCAO INVALIDA DA SSA NO CALL ISRT, REPL
OU
DLET. NUM CALL GSAM CORRIJA A RSA.
AK - EXPLANACAO: A SSA CONTEM UM FIELD NAME
INVALIDO E NAO DEFINI-
DO
NA DBD. O NUMERO NO CAMPO INDICADOR DE NIVEL NA DB-PCB E O
NUMERO DO NIVEL DA SSA QUE CONTEM O NOME INVALIDO
VOCE
PODE TAMBEM RECEBER ESTE STATUS CODE SE O PGM ESTA ACES-
SANDO UM FILHO LOGICO ATRAVES DO PAI LOGICO. O DL/I RETORNA
AK
SE O CAMPO ESPECIFICADO NA SSA FOI DEFINIDO PARA UM SEGMEN
TO FILHO LOGICO E ELE INCLUE PELO
MENOS UMA PARTE DA CHAVE
CONCATENADA DO PAI LOGICO
-
ATITUDE: CORRIJA A SSA
AL - EXPLANACAO: UM PGM BATCH EMITIU UM
MESSAGE CALL OU ROLB E
REFERENCIOU UM I/O PCB.
-
ATITUDE: CORRIJA O PGM . PGM'S BATCH NAO PODEM EMITIR MESSAGE
CALL'S OU ROLB
AM - EXPLANACAO: A CALL FUNCTION NAO E
COMPATIVEL COM A OPCAO DE
PROCESSAMENTO NA PCB. SENSITIVIDADE DE SEGMENTO OU O CODIGO
DE
TRANSACAO DEFINIDO. NUMERO DE NIVEL NA PCB INDICA O NIVEL
NA
SSA QUE ESTA INVALIDO. ALGUMAS DAS RAZOES DESTE ESTATUS
SAO:
.EMISSAO DE UM CALL DE RECUPERACAO COM O COMMAND CODE NUM PGM
QUE
NAO TEM A OPCAO DE PROCESSAMENTO ESPECIFICADA NA DB PCB
QUE
FOI UTILIZADA PARA O CALL
.EMISSAO DE UM CALL DE ISRT COM O COMMAND CODE NUMA MPP OU
EMP QUE NAO TEM A OPCAO DE PROCESSAMENTO
ESPECIFICADO NA DB
PCB
REFERENCIADA PELO CALL. OS PGM'S BATCH NAO PRECISAM DA
OPCAO DE PROCESSAMENTO PARA
EMITIR UM CALL ISRT COM O COM
MAND CODE D, A MENOS QUE O PGM USE SENSITIVIDADE DE CAMPOS
.A
OPCAO DE PROCESSAMENTO E
....
-
ATITUDE: CORRIJA O PGM . PGM'S BATCH NAO PODEM EMITIR MESSAGE
CALL'S OU ROLB
CC - EXPLANACAO: O IMS/VS EXECUTOU O
COMANDO E RETORNOU UMA OU
MAIS
RESPOSTAS AO COMANDO
-
ATITUDE: SEU PGM DEVE EMITIR TANTOS CALL COMO QUANTOS FOREM
NECESSARIOS PARA RECUPERAR AS RESPOSTAS.
CD - EXPLANACAO: O COMANDO FORNECIDO NUM
CALL CMD VIOLA A SEGURAN-
CA.
OU O PGM DE APLICACAO NAO ESTA AUTORIZADO PARA EMITIR
CALL'S CMD. O IMS/VS NAO EXECUTA O COMANDO OU DEVOLVE QUAL-
QUER
RESPOSTA.
-
ATITUDE: CORRIJA O COMANDO. SE NECESSARIO VERIFIQUE COM A
PESSOA RESPONSAVEL PELA SEGURANCA PARA SABER SE AO SEU PGM
ESTA
RESTRINGINDO O USO DO CALL.
CE - EXPLANACAO: O IMS/VS REESCHEDULOU A
MENSAGEM QUE ESTE CALL GU
RECUPEROU DESDE O ULTIMO CALL CMD. O PGM NAO ALCANCOU UM PON-
TO
DE SINCRONISMO QUANDO A MENSAGEM FOI REESCHEDULADA
- ATITUDE: ESTE STATUS E APENAS
INFORMATIVO
Nenhum comentário: